AC High Voltage Low Capacity Test Set - PD Free
Product Code : 05
Brand Name : RE
Price And Quantity
  • Price Range
  • 350000 - 3500000 INR
  • Minimum Order Quantity
Trade Information
  • FOB Port
  • Delhi
  • Payment Terms
  • Cash on Delivery (COD), Cash in Advance (CID), Cheque, Letter of Credit (L/C), Telegraphic Transfer (T/T)
  • Supply Ability
  • 5 Per Month
  • Delivery Time
  • 4 Week
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Packaging Details
  • Bubble Rap Packing Wooden packing with water proof or as per customer requirement.
  • Main Export Market(s)
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001:2008 ISO : 14000
Product Description

Description / Overview

AC High Voltage Low capacity testers are  specially designed for testing Insulators , CT’s PT’s ,  Low dielectric capacitive electrical equipment, transformers etc. as per National and International  Standards.  During  manufacturing each unit is tested at multiple stages, thus ensuring consistency and best  quality. These instruments are air cooled, oil cooled or air & oil cooled combined as per design. The units have been manufactured up to 800kV and up to 200kVA.The units have type of tests such as dry withstand, wet withstand, breakdown voltage in air/oil, oil insulation, and pollution Test

Accessries

Standard Accessories 

v  Interconnecting Control Cable.

v  Discharge Rod.

Optional Accessories

v  Output HV cable.

v  Interconnecting / input power cable.

v  Earthling lead.

Features 

v  Light in weight

v  Casted Wheel for easy movement


Detailed Specifications

 

Partial Discharge Free High Voltage High Capacity Test Set
Sr. No. ParameterDescription
1Input Voltage220/230 or 380/400V, 50/60HZ AC Supply
2Output VoltageUp to 800KV and 400mA
Integration of reactor after 100KVA.
3Partial Discharge LevelLess than 2pC up to 300kV and less than 10pC up to 600kV
4CapacityUp to 320kVA
5Timer0-9999 Sec./min. Digital
6ControlManual ControlThe unit can be manual/motorized control for voltage variation and push button controlled for HT actuation
Digitized ControlThe unit can be complete with on board digitized panel with or without computer connectivity.
PLC basedThe unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
7MeteringVoltmeter : One Digital type connected on HT side to indicate the output voltage
Scale :  0-800 kV AC.
Ammeter : One Digital type ammeter Connected on earth side to indicate the leakage Current on sample under test.
Scale :  0-40A
Applicable only for type -1
For type -2 and type 3 metering is self contained
8ProtecttionTrippingA fast acting DC relay will isolate the circuit when the current exceeds pre-set level
OverloadThis is used as a  secondary protection  in case the input loads exceeds the preset value
Over voltageThis is used as a  secondary protection  in case the output voltage exceeds the preset value
9InterlockingZero Start InterlockThe unit will have zero start interlocking to avoid the transients on HV transformer and provision for  cage door interlocking shall also be provided.
Earth InterlockIt ensures that HV will not actutae untill good earthing is not provided
10TerminationThe HT output on suitable HT insulator and other point at earth potential will be brought out on suitable insulator
11Control PanelThe control panel is designed for five unique purposes.
1 -Control
2- Measure 
3- Protect (Active and Passive) 
4- Tripping
5 -Annunciate
12Reactor A Parallel / series  reactor (LT and HT) when provided in the system resonates with the capacitive current generated during the dielectric testing of any component / equipment / system. It generally consist of motorised moving coil and fixed reactor. It operates up to a Q-factor of 20.
13HV TransformerThe transformers are designed and manufactured as per IS /IEC guidelines. Single /  Multiple stage stepup transformers are utilized  for achiving the desired voltage. The units are designed and manufactured using the  preeminent material from India and Abroad. The coils are vacuum impregnated and insulated with High Quality EHV Grade transformer oil as per relevant IS and IEC Standard

 


RECTIFIERS & ELECTRONICS PVT. LTD.

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.




RECTIFIERS & ELECTRONICS PVT. LTD.
10/3, DLF Industrial Area, Moti Nagar, New Delhi - 110015, India
Phone :+918286086347
Fax :91-11-25438460/41425853
Mr. Manish Arora (Director)
Mobile :+918286086347
Trust Stamp
Product Showcase
Send SMS Send Inquiry