Primary Current Injection Test Set

Primary Current Injection Test Set
Product Code : 22
Brand Name : RE
Price And Quantity
  • Minimum Order Quantity
  • 1
  • Price Range
  • 150000 - 3000000 INR
  • Minimum Order Quantity
Trade Information
  • FOB Port
  • Delhi
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID), Cheque, Letter of Credit (L/C), Telegraphic Transfer (T/T)
  • Supply Ability
  • 5 Per Month
  • Delivery Time
  • 4 to 5 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • Wooden pack with water proof covering Bubble Rap or as per customer requirement.
  • Main Export Market(s)
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001:2008 ISO : 14000
Product Description

Product Description

Description 

Primary Current Injection Test Sets are used to loading, Calibration and testing of CT's bimetals relays, Protection relays etc. Mostly Primary Injection Test set are designed as per customer's specification. The Primary Injections Test sets are of 15 minutes ON/30Minutes OFF duty i.e. testing duty only. Loading transformers are design for continuous use for Temperature Rise or bus duct/Bus Bar etc. Optional accessories requirement may include cable termination, timer, Temperature Indicator, multiple contactor, individual Phase control etc. Equipments are Compact in nature. It is available in portable trolley type/stationery type model And Optional digital/analogue timer. Main Transformer up to 25,000Amps.

 

Features

 Electronic Parameter Monitoring.

Multiple safety interlocks for the operator.

Rugged in construction for site application.

 


Detailed Technical Specifications

 

Three Phase Primary Current Injection Test Set
Sr. No.ParametersDescription
1I/p Voltage 380/ 400V Three Phase 50/ 60HZ AC Supply
2O/p CurrentUp to 25000A
3CapacityUp  to 500KVA
4Duty Cycle Intermittent or countinous
5Control1- The unit can be manual/motorized control for cuurent variation and push button controlled.
2- The unit can be microprocessor based complete with on board digitized panel.
3- The unit can be PLC based complte with computer, HMI memory, printer etc. for operation.
6Power Components1-  Step down transformer : 3 Nos. double wound transformer shall be used for supplying high 
     Current and low voltage for testing.
2 - Auto Transformer  : 3 Nos. Motorized Auto Transformer shall be used for controlling the 
      output voltage from zero to maximum to   control the load Current.
7Metering1- Ampere meter : 3 Nos. Digital Ampremeter shall be provided with 0.5 classes CT to indicate
    the output current.  The size of the amperemeter shall be 96 sq.mm.
2 - Voltmeter : A digital voltmeter with selector switch shall be provided to indicate the output
      voltage each phase/phase to phase, if required.
3 - Line On Indicator : Neon lamp indicators are provided for input indication. 
4- Main ON/OFF switch  : Three pole ON/OFF is provided for input ON &OFF.
8TerminationOutput is brought on Copper bus-bars 
9Control Panel(i) ON/OFF switch
(ii) Separate indication lamps for all three phases in three phase unit.
(iii) Digital Output Ampere meter and Voltmeter with selector switch.
(iv) Push buttons for raising and lowering the Output current separately
      for each phase with change over switch and Push buttons for raising current
      of all the phases simultaneously
10Regulating Transformer
Will be suitable for Motorized operation having limit switches, lifting arrangement
for Regulating Transformer and for the whole unit, Input & Output Indicators.  
The whole unit will be fitted with suitable input 3 Phase 4 Wire and will be mounted
 on 6â€Â casted wheels.Will be suitable for Motorized or manual operation having limit switches.
11Step Down TransformerShall be air cooled type.  Primary winding having DCC insulation and secondary winding of
bare copper strip (RYB & Neutral).  The unit shall be housed in a MS Sheet body supported 
an angle iron frame.  Output RYB-N shall be brought out on Copper bus- bar of electrolyte grade.  
The output with connected star so in case of need each phase can be used independently.  
Casted wheels shall be of 6" dia for easy movement. 

RECTIFIERS & ELECTRONICS PVT. LTD.

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.




RECTIFIERS & ELECTRONICS PVT. LTD.
10/3, DLF Industrial Area, Moti Nagar, New Delhi - 110015, India
Phone :+918286086347
Fax :91-11-25438460/41425853
Mr. Manish Arora (Director)
Mobile :+918286086347
Trust Stamp
Product Showcase
Send SMS Send Inquiry