Cookie Img
Back to top
Send SMS Send Inquiry
Home » Products » AC High Voltage » Tracking Erosion Index

Tracking Erosion Index

Tracking Erosion Index
Product Code : 10
Brand Name : RE
Price And Quantity
  • Minimum Order Quantity
  • 1
  • Unit of Measure
  • Piece/Pieces
  • Price Range
  • 150000 - 500000 INR
  • Minimum Order Quantity
Trade Information
  • FOB Port
  • Delhi
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T)
  • Supply Ability
  • 20 Per Month
  • Delivery Time
  • 3-4 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • Bubble Rap Packing Wooden packing with water proof or as per customer requirement.
  • Main Export Market(s)
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO : 9001 : 2008 ISO : 14000
Product Description

Description

Tracking Resistance Erosion Test Equipment is used for checking the relative behavior of solid electrical insulating material with regard to their susceptibility to surface tracking when exposed under electric stresses, to water and contaminants, from the surroundings.

The grading of materials arrived at by checking the tracking index may possibly differ from that obtained by utilizing other checking methods for the measurements of the tracking index.

The results obtained by checking tracking index are not used directly for evaluation of safe creepage distances while designing any electrical apparatus.

With this apparatus drops of an electrolyte are dropped at defined time interval to the surface of insulating materials between two electrodes to which a voltage is applied.

The number of drops at which break down occurs across the surface is the function of voltage

The numerical values of the voltage corresponding to the asymptotes defines the tracking resistance.The value of voltage corresponding to number of drops is taken as the comparative index. (This test should be done as fast as possible)

The number of drops to cause tracking at value of predetermined test voltage 10% below the number of drops value is indicated as the degree to which the reported  comparative tracking

 

Accessries

  Output AC voltage and AC current cable.

  Output DC voltage cable.

 

Features

 Technologically advanced design that helped make  proper  use  of space and minimize the size of the equipment.

 Zero start interlocking, earthing, electrode box, cage door interlocking are some of the features that make the equipment very safe for the user

 The equipment has been made so that it is very simple to operate, thus any person after learning once can operate it

 

Detailed Specifications

 

Input voltage                           :           220/ 230 Volts, Single phase 50/60 Hz. AC supply.

Output voltage                        :           0-10KV

Output Current                       :           100mA

Capacity                                  :           1 KVA

Rating                                     :           Testing duty (Continuous).

Cooling                                   :           Air cooled.

(Peristaltic Pump Section)

No. of Channel                       :           Up to Five

RPM                                        :           0.01 to 9.99

Flow Rate                               :           0.12 to 600 ml/hr

1.2 to 120 ml/hr in 1 mm I.D. tubing

3.0 to 300 ml/hr in 2 mm I.D. tubing

6.0 to 600 ml/hr in 3 mm I.D. tubing

Tubing

(with 1 or 1.5 mm wall thickness)

Pressure                                               :           Up to 2 kg/sq.cm

Supply                                                 :           230 v, 50 Hz, A.C.

Motor                                                  :           DC Stepper Motor

Temp. range                                        :           0 to 50 deg. C

 

The Unit  consists of the following :

1) HV Section

2) Peristaltic Pump Section

 

(HV Section)

  Regulating Transformer

  Main Transformer

  LT ON Indicator

  Fault indicator

  HT ON Indicator

  Push button actuate HT ON

  Push button cut off HT

  KV Meter 0-10KV

  mA Meter 0-100mA

  Knob to increase and decrease of output voltage

  Trip Selector

(Peristaltic Pump Section)

The Parasitic pump is a single channel pump for the use in laboratory and extensively in industrial applications where accurate flow rate is essential.  Pumping action is done by a roller cage driven by stepper motor. The motor and internal are almost independent of temperature.  This pump has load and line compensation circuit.  The rollers are made up of carbon filled nylon for trouble free operation.  The electronic circuit provides constant flow rate even there is line voltage or load variation.

 


RECTIFIERS & ELECTRONICS PVT. LTD.

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.




RECTIFIERS & ELECTRONICS PVT. LTD.
10/3, DLF Industrial Area, Moti Nagar, New Delhi - 110015, India
Phone :+918286086347
Fax :91-11-25438460/41425853
Mr. Manish Arora (Director)
Mobile :+918286086347
Trust Stamp
Product Showcase
Send SMS Send Inquiry