Product Details:

  • Product Type For Surface Tracking of Solid Insulating Material
  • Material MS
  • Measuring Voltage Range Up to 800kV and 250mA Volt (v)
  • Operating Temperature 0-50 Deg. C Celsius (oC)
  • Frequency (MHz) 50Hz
  • Insulation Box High Voltage on Specific Designed Electrodes
  • Protection System Over Load, Over Voltage and Earth Fault Protection
  • Click to View more
X

AC high Voltage Tracking Erosion Index Test Set Up to 10kV and 100mA Price And Quantity

  • 01 Set
  • 50000.00 - 100000.00 INR/Set

AC high Voltage Tracking Erosion Index Test Set Up to 10kV and 100mA Product Specifications

  • Depends on kV Rating required by Customer
  • 50Hz
  • For Surface Tracking of Solid Insulating Material
  • Depends on kV Rating required by Customer Millimeter (mm)
  • Up to 800kV and 250mA Volt (v)
  • MS
  • Over Load, Over Voltage and Earth Fault Protection
  • 0-50 Deg. C Celsius (oC)
  • 12 Months from Manufacturing
  • Depends on kV Rating required by Customer
  • High Voltage on Specific Designed Electrodes
  • RAL-7032

AC high Voltage Tracking Erosion Index Test Set Up to 10kV and 100mA Trade Information

  • Delhi
  • 3 Set Per Year
  • 8 Week
  • Yes
  • Contact us for information regarding our sample policy
  • Bubble Wrap Packing Wooden packing with waterproof or As per customer requirement.
  • All India
  • ISO : 9001 : 2008 ISO : 14001 and OHSAS : 18000

Product Description

Description :-

Tracking Resistance Erosion Test Equipment is used for checking the relative behavior of solid electrical insulating material with regard to their susceptibility to surface tracking when exposed under electric stresses, to water and contaminants, from the surroundings.

The grading of materials arrived at by checking the tracking index may possibly differ from that obtained by utilizing other checking methods for the measurements of the tracking index.

The results obtained by checking tracking index are not used directly for evaluation of safe creepage distances while designing any electrical apparatus.

With this apparatus drops of an electrolyte are dropped at defined time interval to the surface of insulating materials between two electrodes to which a voltage is applied.

The number of drops at which break down occurs across the surface is the function of voltage.

The numerical values of the voltage corresponding to the asymptotes defines the tracking resistance.The value of voltage corresponding to number of drops is taken as the comparative index. (This test should be done as fast as possible).

The number of drops to cause tracking at value of predetermined test voltage 10% below the number of drops value is indicated as the degree to which the reported comparative tracking.

Special Features :-

  • Technologically advanced design that helped make proper use of space and minimize the size of the equipment.

  • Zero start interlocking, earthing, electrode box, cage door interlocking are some of the features that make the equipment very safe for the user

  • The equipment has been made so that it is very simple to operate, thus any person after learning once can operate it.

Standard Accessories :-

  • Main Unit

Technical Specifications :-

Input voltage

220/ 230 Volts, Single phase 50/60 Hz. AC supply.

Output voltage

0-10KV

Output Current

100mA

Capacity

1 KVA

Rating

Testing duty (Continuous)

Cooling

Air cooled

(Peristaltic Pump Section)

No. of Channel

Up to Five

RPM

0.01 to 9.99

Flow Rate

0.12 to 600 ml/hr

1.2 to 120 ml/hr in 1 mm I.D. tubing

3.0 to 300 ml/hr in 2 mm I.D. tubing

6.0 to 600 ml/hr in 3 mm I.D. tubing

Tubing (with 1 or 1.5 mm wall thickness)

Pressure

Up to 2 kg/sq.cm

Supply

230 v, 50 Hz, A.C.

Motor

DC Stepper Motor

Temp. range

0 to 50 deg. C

The Unit consists of the following :

1) HV Section

2) Peristaltic Pump Section

(HV Section)

  • Regulating Transformer

  • Main Transformer

  • LT ON Indicator

  • Fault indicator

  • HT ON Indicator

  • Push button actuate HT ON

  • Push button cut off HT

  • KV Meter 0-10KV

  • mA Meter 0-100mA

  • Knob to increase and decrease of output voltage

  • Trip Selector

(Peristaltic Pump Section)

The Parasitic pump is a single channel pump for the use in laboratory and extensively in industrial applications where accurate flow rate is essential. Pumping action is done by a roller cage driven by stepper motor. The motor and internal are almost independent of temperature. This pump has load and line compensation circuit. The rollers are made up of carbon filled nylon for trouble free operation. The electronic circuit provides constant flow rate even there is line voltage or load variation.

Other Products in 'AC High Voltage' category




Back to top


RFQ Request For Quotation
Get Quotes For Your Buying Requirement. Tell Suppliers What You Need.
I agree to abide by all the Terms and Conditions of tradeindia.com
trade india member
Rectifier & Electronics Pvt. Ltd. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.